Tripp Lite 27.6kW 3-Phase Switched PDU, 220/230V (24-C13 & 6-C19), IEC309 63A Red, 380/400V Input, 6ft cord, 0U Vertical

GTIN (EAN/UPC):
Data-sheet quality:
created/standardized by Icecat
Product views:
89642
Info modified on:
10 Aug 2024, 09:40:11
Long product name Tripp Lite 27.6kW 3-Phase Switched PDU, 220/230V (24-C13 & 6-C19), IEC309 63A Red, 380/400V Input, 6ft cord, 0U Vertical:

27.6kW 3-Phase Switched PDU, 220/230V (24-C13 & 6-C19), IEC309 63A Red, 380/400V Input, 6ft cord, 0U Vertical

Tripp Lite 27.6kW 3-Phase Switched PDU, 220/230V (24-C13 & 6-C19), IEC309 63A Red, 380/400V Input, 6ft cord, 0U Vertical:

Tripp Lite 3 phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption per-phase or per-receptacle. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps per-phase or per-receptacle can be displayed locally via visual meter or remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip. Highly accurate current metering offers +/-1% billing-grade current monitoring and recording ability for each output phase, breakered load bank and individual outlet.
- 27.6kW Switched 380/400V input, 220/230V output PDU with built-in web/network interface
- IEC309 63A Red (3P+N+E) 380/400V 3 phase input with 6 ft. / 1.8m line cord
- 0U, 70 inch / 178cm vertical form factor
- 30 switched 220/230V outlets (24 C13, 6 C19) in 6 separately breakered 20A single phase load banks
- Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis
- Enables reboot of locked equipment, custom power-on/power-off sequences, load shedding of optional loads and disabling unused outlets
- Network interface provides PDU control and data regarding input voltage and load levels per-outlet, per-breaker and per-phase
- Built-in local digital display and remote web/network interface reports detailed voltage, amperage and kilowatt output values per outlet, per breaker and per phase with additional reporting options for power unbalance percentage, IP address and sensor based temperature and humidity data (requires ENVIROSENSE sensor)
- In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors

Short summary description Tripp Lite 27.6kW 3-Phase Switched PDU, 220/230V (24-C13 & 6-C19), IEC309 63A Red, 380/400V Input, 6ft cord, 0U Vertical:

Tripp Lite 27.6kW 3-Phase Switched PDU, 220/230V (24-C13 & 6-C19), IEC309 63A Red, 380/400V Input, 6ft cord, 0U Vertical, Switched, 0U, Vertical, Steel, Black, LCD

Long summary description Tripp Lite 27.6kW 3-Phase Switched PDU, 220/230V (24-C13 & 6-C19), IEC309 63A Red, 380/400V Input, 6ft cord, 0U Vertical:

Tripp Lite 27.6kW 3-Phase Switched PDU, 220/230V (24-C13 & 6-C19), IEC309 63A Red, 380/400V Input, 6ft cord, 0U Vertical. PDU types: Switched, Rack capacity: 0U, Mounting: Vertical. AC outlets quantity: 30 AC outlet(s), AC outlet types: C13 coupler, C9 coupler, Power plug: IEC309. Cable length: 1.8 m, Certification: TAA, CE. Nominal input voltage: 380-400 V, Maximum current: 63 A, Nominal output voltage: 220-240 V. Dimensions (WxDxH): 55.1 x 64 x 1778 mm, Weight: 8.7 kg

Warranty:
5-year limited warranty
Embed the product datasheet into your content