Ampmeter PDU. 12 V
Article code :
The brand's unique identifier for a product. Multiple product codes can be mapped to one mother product code if the specifications are identical. We map away wrong codes or sometimes logistic variants.
Category :
A power distribution unit (PDU) is a device with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within a data center.
Power Distribution Units (PDUs)
Data-sheet quality: created/standardized by Icecat
The quality of the data-sheets can be on several levels:
only logistic data imported: we have only basic data imported from a supplier, a data-sheet is not yet created by an editor.
created by Eaton: a data-sheet is imported from an official source from a manufacturer. But the data-sheet is not yet standardized by an Icecat editor.
created/standardized by Icecat: the data-sheet is created or standardized by an Icecat editor.
Included since: 13 Sep 2005
The date Icecat noticed for the first time that this product was included in the price list of a channel partner
Info modified on: 25 Feb 2016 19:45:44
The date of the most recent change of the data-sheet in Icecat's system
Product views: 14956
This statistic is based on the 61915 using ecommerce sites (eshops, distributors, comparison sites, ecommerce ASPs, purchase systems, etc) daily downloading this Icecat data-sheet since 13-09-05 Only sponsoring brands are included in the free Open Icecat content distribution as used by 60276 free Open Icecat users.
Long product name Eaton Ampmeter PDU. 12 V:
The short editorial description of Eaton Ampmeter PDU. 12 V
Ampmeter PDU, 12 x IEC 320 C 13, cable locking system

Marketing text Eaton Ampmeter PDU. 12 V

The official marketing text of Eaton Ampmeter PDU. 12 V as supplied by the manufacturer
High availability

Input Current monitoring of the connected equipment in the rack cabinet can significantly enhance- IT & network equipment uptime. Each Intelligent PDU includes a digital display indicator for local, real-time reading of the aggregate current used by the connected devices. NM (Network-Managed) versions add remote in-band or out-of-band supervision.

Setting up the alarm threshold of the PDU input current will provide a safety margin. This will dramatically reduce the risk of upstream protection tripping due to:
◗ Overload. For example, installation of new servers is routinely needed but they may exceed the rated power draw.
◗ Inrush current generated by simultaneous device start-up when installed in the same cabinet. Switched PDUs allow for sequencial start-up to prevent this.

Supervision and remote maintenance

70% of locked-up server issues are solved through a power reboot. Switched PDUs can achieve this task remotely to save time and money. MGE designed the Ampmeter PDU 12 NM 2U for dual power supply devices like blade servers. NM models provide 2 ports for connection of temperature/humidity sensors to simultaneously monitor the environment conditions at the bottom and top of the rack enclosure. Status, conditions and thresholds of NM versions can also be monitored and controlled from a web interface. These products can also be integrated with MGE Enterprise Power Manager supervision platform or any NMS by means of their SNMP protocol.

Safety and reliability

Safety of the PDU remote operation is ensured by:
◗ Encryption and authentication (SSL/SSH).
◗ Different administration levels allowing to lock some strategic outlets.
◗ "Out-of–band" administration to manage the PDU remotely even in case of a network failure.
◗ Cable lock system for inlet and outlets.

Easy installation
Based on the PDU model, mounting options include horizontal (1 or 2U) or vertical (0U, labelled as "V").
Short summary description Eaton Ampmeter PDU. 12 V:
This short summary of the Eaton Ampmeter PDU. 12 V data-sheet is auto-generated and uses the product title and the first six key specs.
Eaton Ampmeter PDU. 12 V, 0 - 50 °C, 1 x IEC 309, 1.77 x 2.24 x 31.3" (45 x 57 x 794 mm), 12 x IEC 320 C 13, CE, UL, TUV
Long summary description Eaton Ampmeter PDU. 12 V:
This is an auto-generated long summary of Eaton Ampmeter PDU. 12 V based on the first three specs of the first five spec groups.
Eaton Ampmeter PDU. 12 V. Maximum input current per phase: 32 A. Input connection type: 1 x IEC 309, Output connections: 12 x IEC 320 C 13. Cable length: 78.7" (2 m). Dimensions (WxDxH): 1.77 x 2.24 x 31.3" (45 x 57 x 794 mm), Weight: 11.7 lbs (5.3 kg). Certification: CE, UL, TUV
This is a demo of a seamless insert of an Icecat LIVE product data-sheet in your website. Imagine that this responsive data-sheet is included in the product page of your webshop. How to integrate Icecat LIVE JavaScript.
Energy Management
Nominal input voltage*
The voltage which the manufacturer recommends that the device needs to operate normally.
Maximum input current per phase
32 A
Ports & interfaces
Input connection type
The type of connection /port for the input(s) into this device e.g. USB.
1 x IEC 309
Output connections
12 x IEC 320 C 13
Cable length
How long the cable is.
2 m
Operational Conditions
Operating temperature range (T-T)
The minimum and maximum temperatures at which the product can be safely operated.
0 - 50°C
Weight & Dimensions
Dimensions (WxDxH)
Dimensions of the product (Width x Depth x Height).
1.77 x 2.24 x 31.3" (45 x 57 x 794 mm)
Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
11.7 lbs (5,3 kg)
Article code
Price from
Eaton Ampmeter PDU. 12 NM 2U
Eaton Ampmeter PDU. 12 NM 2U
(show image)
Here, we only show product images of sponsoring brands that joined Open Icecat as product images can be subject to copyrights. Icecat can be of assistance in securing the necessary permissions or implementing a brand's Digital Rights Management policies. Login to view all product specs or request a Full Icecat subscription to download product specs.